Contamination · November 2026

Field testing for physical contamination

Plastic, glass and metal are the contaminants composters worry about most. They arrive in feedstock, survive the process, and turn up in finished compost, where buyers notice them. The industry's standard set of compost test methods, TMECC, is now being revised, and the foundation leading the revision reports that a field method for physical contamination is in high demand.

How contamination is measured today

Composters use three kinds of check, from quickest to most exact.

  1. A look at the tipping floor. When a load is tipped, an operator scans it for plastic, glass and metal, and may grade it or estimate how much of it is covered in trash. It's fast, but it depends on who is looking, and it usually leaves no record.
  2. A field sample. California's CalRecycle publishes an optional field method: a 30-gallon composite sample built from twelve grabs around the pile, with contaminants picked out by hand and weighed. It gives a number, but it takes time, and it is meant for coarse material such as mulch and compost overs.
  3. Lab analysis. A sample is sent to a lab, which sieves it and weighs the contaminants it finds. It's the most exact of the three, but it takes days or weeks, and each test covers only the sample that was sent.

What the industry is asking for

The Compost Research & Education Foundation (CREF) is producing a third edition of TMECC. BioCycle's report on the project (Juliana Beecher, September 8, 2026) says CREF has received many requests for new ways to measure physical contamination, and that:

“A field-based test method for physical contamination is in high demand.”

BioCycle, “Compost Test Methods Update, Part 1”

CREF's TMECC Program Manager calls the current lab method “a tedious method, based on the laboratory feedback we've received.” Producers and users, the article says, want field methods for faster decisions.

How VCAT measures contamination

VCAT is a phone app for compost facilities.

That makes it quick enough to use on every load and every batch, not only on the samples you send to a lab, and it leaves a dated record, with photos, that you can take back to a hauler.

What VCAT's number is, and what it isn't

Because surface and weight measure different things, we don't expect one to predict the other closely. We plan to compare VCAT's readings with lab and field results on the same material, and we'll share what we find.

Want to see what VCAT makes of your own loads and batches?

Talk to us about trying VCAT arrow_forward

Or read the FAQ and see pricing.

Sources